Medium Voltage URD (Underground Residential Distribution) Cables
[row class=prodetails]
[column lg=”5″ md=”12″ sm=”12″ xs=”12″ ]
[/column]
[column lg=”7″ md=”12″ sm=”12″ xs=”12″ ]
Applicable: cables are predominantly used for primary underground distribution in conduit systems suitable for use in wet or drylocations, direct burial, underground duct, and where exposed to sunlight. To be used at 35,000 volts or less andat conductor temperatures not to exceed 90°C(MV90) or 150°C(MV-105) for normal operation.
Rated Voltage:5KV, 8KV, 15KV, 25KV, 28KV, 35KV, 46KV
Conductor: stranded Aluminum / Copper wire
Strand shield: extruded semi-conducting strand shield
Insulation: cross-linked polyethylene
Insulation shield: extruded semi-conducting insulation shield
Neutral wires: 33% copper concentric neutral wires
Jacket: Non-conducting low density PE encapsulating jacket
Operating temperature: 90℃ , 105℃
Conductors are available with 100% or 133% insulation level
[popup_close tag=”p” classes=”button-center”][/popup_close]
[/column]
[/row]
Technical Data
[su_spoiler title=”15kV URD EPR 100% INSULATION LEVEL” style=”fancy” icon=”plus-circle”]
[row]
| Weight 1000 feet (lbs.) | Allowable Ampacities+ | ||||||||||||
| Phase Conductor | Neutral | Thickness Per Cond. (mils) | Nominal Diameter (mils) | ||||||||||
| Size (AWG or kcmil) | Insul. Shield min. Point | Bare Phase Cond. | Over Insul. Shield | ||||||||||
| Strand- ing | No. of Wires | Size (AWG) | Nominal Insul. | Approx. Jkt. | Over Insul. | Comp. Cable | Comp. Cable | Direct Burial | In Ducts | ||||
| ALUMINUM CONDUCTOR – 100% INSULATION LEVEL | |||||||||||||
| 2 | Solid | 10 | 14 | 175 | 30 | 50 | 258 | 653 | 733 | 961 | 485 | 168* | 119* |
| 2 | 7 | 10 | 14 | 175 | 30 | 50 | 283 | 678 | 758 | 986 | 504 | 168* | 119* |
| 1 | Solid | 13 | 14 | 175 | 30 | 50 | 289 | 685 | 765 | 993 | 555 | 193* | 137* |
| 1 | 19 | 13 | 14 | 175 | 30 | 50 | 322 | 718 | 798 | 1026 | 577 | 193* | 137* |
| 1/0 | Solid | 16 | 14 | 175 | 30 | 50 | 325 | 720 | 800 | 1028 | 629 | 218* | 155* |
| 1/0 | 19 | 16 | 14 | 175 | 30 | 50 | 352 | 748 | 828 | 1056 | 648 | 218* | 155* |
| 2/0 | 19 | 20 | 14 | 175 | 30 | 50 | 395 | 790 | 870 | 1098 | 745 | 248* | 177* |
| 3/0 | 19 | 25 | 14 | 175 | 30 | 50 | 443 | 838 | 918 | 1146 | 862 | 284* | 201* |
| 4/0 | 19 | 20 | 12 | 175 | 30 | 50 | 498 | 893 | 973 | 1234 | 1042 | 324* | 230* |
| 250 | 37 | 16 | 10 | 175 | 30 | 50 | 558 | 963 | 1043 | 1346 | 1268 | 360* | 257* |
| 350 | 37 | 18 | 14 | 175 | 40 | 50 | 661 | 1068 | 1168 | 1396 | 1118 | 389** | 319** |
| 500 | 37 | 25 | 14 | 175 | 40 | 50 | 789 | 1193 | 1293 | 1521 | 1419 | 468** | 384** |
| 750 | 61 | 24 | 12 | 175 | 40 | 80 | 968 | 1383 | 1483 | 1798 | 2030 | 569** | 468** |
| 1000 | 61 | 20 | 10 | 175 | 40 | 80 | 1117 | 1530 | 1630 | 1988 | 2567 | 642** | 542** |
| 1250 | 91 | 25 | 10 | 220 | 55 | 80 | 1250 | 1765 | 1895 | 2253 | 3278 | 688** | 604** |
| 1500 | 91 | 30 | 10 | 220 | 55 | 80 | 1370 | 1885 | 2015 | 2373 | 3762 | 726** | 637** |
| COPPER CONDUCTOR – 100% INSULATION LEVEL | |||||||||||||
| 2 | Solid | 16 | 14 | 175 | 30 | 50 | 258 | 653 | 733 | 961 | 697 | 210* | 150* |
| 2 | 7 | 16 | 14 | 175 | 30 | 50 | 283 | 678 | 758 | 986 | 719 | 210* | 150* |
| 1 | Solid | 20 | 14 | 175 | 30 | 50 | 289 | 685 | 765 | 993 | 815 | 240* | 171* |
| 1 | 19 | 20 | 14 | 175 | 30 | 50 | 322 | 718 | 798 | 1026 | 841 | 240* | 171* |
| 1/0 | Solid | 25 | 14 | 175 | 30 | 50 | 325 | 720 | 800 | 1028 | 959 | 273* | 194* |
| 1/0 | 19 | 25 | 14 | 175 | 30 | 50 | 362 | 758 | 838 | 1066 | 991 | 273* | 194* |
| 2/0 | 19 | 20 | 12 | 175 | 30 | 50 | 405 | 800 | 880 | 1142 | 1204 | 313* | 224* |
| 3/0 | 19 | 25 | 12 | 175 | 30 | 50 | 456 | 853 | 933 | 1194 | 1437 | 358* | 255* |
| 4/0 | 19 | 20 | 10 | 175 | 30 | 50 | 512 | 908 | 988 | 1291 | 1768 | 410* | 293* |
| 250 | 37 | 24 | 10 | 175 | 30 | 50 | 558 | 963 | 1043 | 1346 | 2047 | 446* | 322* |
| 350 | 37 | 18 | 12 | 175 | 40 | 50 | 661 | 1068 | 1168 | 1429 | 2027 | 489** | 400** |
| 500 | 37 | 26 | 12 | 175 | 40 | 50 | 789 | 1193 | 1293 | 1554 | 2722 | 577** | 472** |
| 750 | 61 | 25 | 10 | 175 | 40 | 80 | 968 | 1383 | 1483 | 1840 | 3990 | 649** | 532** |
| 1000 | 61 | 26 | 9 | 175 | 40 | 80 | 1117 | 1530 | 1630 | 2013 | 5136 | 720** | 630** |
| 1250 | 91 | 26 | 8 | 220 | 55 | 80 | 1250 | 1765 | 1895 | 2306 | 6535 | 760** | 667** |
| + Ampacities shown assume use of 100% load factor, 60 Hz current, 36″ burial depth, 20°C ambient temperature, 90°C | |||||||||||||
| conductor temperature, earth RHO 90, insulation and shield RHO 400 | |||||||||||||
| * Full neutral construction (Ampacities assume – single phase circuit, one cable) | |||||||||||||
| ** 1/3 neutral cable (Ampacities assume – three phase circuit, 3 cables triplexed, multi-point grounding per ICEA methods) | |||||||||||||
[/row]
Get a free quote by e-mail: sales@huadongtest.hdlightningprotection.com
[popup_close tag=”p” classes=”button-center”][/popup_close]
[/su_spoiler]
[su_spoiler title=”15kV URD EPR 133% INSULATION LEVEL” style=”fancy” icon=”plus-circle”]
[row]
| Phase Conductor | Thickness Per Cond. (mils) | Diameter (mils) | Weight 1000 feet (lbs.) | Allowable Ampacities+ | |||||||||
| Neutral | |||||||||||||
| Insul. Shield min. Point | |||||||||||||
| Size (AWG or kcmil) | Strand- ing | No. of Wires | Size (AWG) | Nominal Insul. | Approx. Jkt. | Bare Phase Cond. | Over Insul. | Over Insul. Shield | Comp. Cable | Comp. Cable | Direct Burial | In Ducts | |
| ALUMINUM CONDUCTOR – 0.220″ INSULATION – 133% INSULATION LEVEL | |||||||||||||
| 2 | Solid | 10 | 14 | 220 | 30 | 50 | 258 | 745 | 825 | 1053 | 556 | 168* | 119* |
| 2 | 7 | 10 | 14 | 220 | 30 | 50 | 283 | 770 | 850 | 1078 | 577 | 168* | 119* |
| 1 | Solid | 13 | 14 | 220 | 30 | 50 | 289 | 778 | 858 | 1086 | 628 | 193* | 137* |
| 1 | 19 | 13 | 14 | 220 | 30 | 50 | 322 | 810 | 890 | 1118 | 652 | 193* | 137* |
| 1/0 | Solid | 16 | 14 | 220 | 30 | 50 | 325 | 813 | 893 | 1121 | 705 | 218* | 155* |
| 1/0 | 19 | 16 | 14 | 220 | 30 | 50 | 352 | 840 | 920 | 1148 | 726 | 218* | 155* |
| 2/0 | 19 | 20 | 14 | 220 | 30 | 50 | 395 | 883 | 963 | 1191 | 826 | 248* | 177* |
| 3/0 | 19 | 25 | 14 | 220 | 30 | 50 | 443 | 930 | 1010 | 1238 | 947 | 284* | 201* |
| 4/0 | 19 | 20 | 12 | 220 | 30 | 50 | 498 | 985 | 1065 | 1327 | 1133 | 324* | 230* |
| 250 | 37 | 16 | 10 | 220 | 40 | 50 | 558 | 1055 | 1155 | 1459 | 1389 | 360* | 257* |
| 350 | 37 | 18 | 14 | 220 | 40 | 50 | 661 | 1158 | 1258 | 1486 | 1219 | 389** | 319** |
| 500 | 37 | 25 | 14 | 220 | 40 | 50 | 789 | 1285 | 1385 | 1613 | 1532 | 468** | 384** |
| 750 | 61 | 24 | 12 | 220 | 40 | 80 | 968 | 1475 | 1575 | 1891 | 2162 | 569** | 468** |
| 1000 | 61 | 20 | 10 | 220 | 55 | 80 | 1117 | 1623 | 1753 | 2110 | 2762 | 642** | 542** |
| 1250 | 91 | 25 | 10 | 220 | 55 | 80 | 1250 | 1765 | 1895 | 2253 | 3278 | 688** | 604** |
| 1500 | 91 | 30 | 10 | 220 | 55 | 80 | 1370 | 1885 | 2015 | 2373 | 3762 | 726** | 637** |
| COPPER CONDUCTOR – 0.220″ INSULATION – 133% INSULATION LEVEL | |||||||||||||
| 2 | Solid | 16 | 14 | 220 | 30 | 50 | 258 | 745 | 825 | 1053 | 768 | 210* | 150* |
| 2 | 7 | 16 | 14 | 220 | 30 | 50 | 283 | 770 | 850 | 1078 | 792 | 210* | 150* |
| 1 | Solid | 20 | 14 | 220 | 30 | 50 | 289 | 778 | 858 | 1086 | 888 | 240* | 171* |
| 1 | 19 | 20 | 14 | 220 | 30 | 50 | 322 | 810 | 890 | 1118 | 916 | 240* | 171* |
| 1/0 | Solid | 25 | 14 | 220 | 30 | 50 | 325 | 813 | 893 | 1121 | 1035 | 273* | 194* |
| 1/0 | 19 | 25 | 14 | 220 | 30 | 50 | 362 | 850 | 930 | 1158 | 1070 | 273* | 194* |
| 2/0 | 19 | 20 | 12 | 220 | 30 | 50 | 405 | 893 | 973 | 1234 | 1288 | 313* | 224* |
| 3/0 | 19 | 25 | 12 | 220 | 30 | 50 | 456 | 943 | 1023 | 1284 | 1523 | 358* | 255* |
| 4/0 | 19 | 20 | 10 | 220 | 30 | 50 | 512 | 1000 | 1080 | 1384 | 1863 | 410* | 293* |
| 250 | 37 | 24 | 10 | 220 | 40 | 50 | 558 | 1055 | 1155 | 1459 | 2168 | 446* | 322* |
| 350 | 37 | 18 | 12 | 220 | 40 | 50 | 661 | 1158 | 1258 | 1519 | 2130 | 489** | 400** |
| 500 | 37 | 26 | 12 | 220 | 40 | 50 | 789 | 1285 | 1385 | 1647 | 2837 | 577** | 472** |
| 750 | 61 | 25 | 10 | 220 | 40 | 80 | 968 | 1475 | 1575 | 1933 | 4125 | 649** | 532** |
| 1000 | 61 | 26 | 9 | 220 | 55 | 80 | 1117 | 1623 | 1753 | 2135 | 5332 | 720** | 630** |
| 1250 | 91 | 26 | 8 | 220 | 55 | 80 | 1250 | 1765 | 1895 | 2306 | 6535 | 760** | 667** |
| + Ampacities shown assume use of 100% load factor, 60 Hz current, 36″ burial depth, 20°C ambient temperature, 90°C conductor temperature, earth RHO 90, insulation and shield RHO 400 | |||||||||||||
| * Full neutral construction (Ampacities assume – single phase circuit, one cable | |||||||||||||
| ** 1/3 neutral cable (Ampacities assume – three phase circuit, 3 cables triplexed, multi-point grounding per ICEA methods) | |||||||||||||
[/row]
Get a free quote by e-mail: sales@huadongtest.hdlightningprotection.com
[popup_close tag=”p” classes=”button-center”][/popup_close]
[/su_spoiler]
HUADONG CABLE GROUP SINCE 1999
Professional Cables and Wires Manufacturer in China
We can design cables according to your requirement
Verified Manufacturer